Management

Alerting indices

The alerting feature creates several indices and one alias. Don’t delete these or modify their contents without using the alerting APIs.

Index Purpose
.opendistro-alerting-alerts Stores ongoing alerts.
.opendistro-alerting-alert-history-<date> Stores a history of completed alerts.
.opendistro-alerting-config Stores monitors, triggers, and destinations.
.opendistro-alerting-alert-history-write (alias) Provides a consistent URI for the .opendistro-alerting-alert-history-<date> index.

Alerting settings

We don’t recommend changing these settings; the defaults should work well for most use cases.

All settings are available using the Elasticsearch _cluster/settings API. None require a restart, and all can be marked persistent or transient.

Setting Default Description
opendistro.alerting.enabled true Whether the alerting plugin is enabled or not. If disabled, all monitors immediately stop running.
opendistro.alerting.input_timeout 30s How long the monitor can take to issue the search request.
opendistro.alerting.bulk_timeout 120s How long the monitor can write alerts to the alert index.
opendistro.alerting.alert_backoff_count 2 The number of retries for writing alerts before the operation fails.
opendistro.alerting.alert_backoff_millis 50ms The amount of time to wait between retries—increases exponentially after each failed retry.
opendistro.alerting.alert_history_rollover_period 12h How often completed alerts are rolled over from the .opendistro-alerts index to .opendistro-alert-history-<date>.
opendistro.alerting.move_alerts_backoff_millis 250 The amount of time to wait between retries—increases exponentially after each failed retry.
opendistro.alerting.move_alerts_backoff_count 3 The number of retries for moving alerts to a deleted state after their monitor or trigger has been deleted.
opendistro.alerting.monitor.max_monitors 1000 The maximum number of monitors users can create.
opendistro.alerting.alert_history_max_age 24h The oldest document the .opendistro-alert-history-<date> index should keep.
opendistro.alerting.alert_history_max_docs 1000 The maximum number of documents the .opendistro-alert-history-<date> index should keep.
opendistro.scheduled_jobs.sweeper.period 5m The alerting feature uses its “job sweeper” component to periodically check for new or updated jobs. This setting is the rate at which the sweeper checks to see if any jobs (monitors) have changed and need to be rescheduled.
opendistro.scheduled_jobs.sweeper.page_size 100 The page size for the sweeper. You shouldn’t need to change this value.
opendistro.scheduled_jobs.sweeper.backoff_millis 50ms The amount of time the sweeper waits between retries—increases exponentially after each failed retry.